Aktuelles
Hochspannungsisolatoren

COMPROTware:Testtool 1.48

Release T.1.48.18 - Builddate 2016-02-09 -- Tested Release

Download

Download the CPTT installation file cptt_1.48.msi (approx. 1530K).
(To install the file, double click the MSI file and follow the installation instructions.)

What is new?

  • Current focus: Modernization of protocol presentation
    • IEC 60870-5-101: Implementation is now based on modernized Dissector-API.
    • IEC 60870-5-102: Implementation is now based on modernized Dissector-API.
    • IEC 60870-5-103: Implementation is now based on modernized Dissector-API.
    • IEC 60870-5-104: Implementation is now based on modernized Dissector-API.
    • IEC 61850: Implementation is now based on modernized Dissector-API.
    • DNP3 serial: Implementation is now based on modernized Dissector-API.
    • DNP3 over LAN/WAN: Implementation is now based on modernized Dissector-API.
    • MODBUS serial: Implementation is now based on modernized Dissector-API.
    • MODBUS TCP/IP: Implementation is now based on modernized Dissector-API.
    • ABB RP570/571: Implementation is now based on modernized Dissector-API.
    • ABB SPA-Bus: Implementation is now based on modernized Dissector-API.
    • Landis&Gyr TG 809: Presentation of the protocol traffic was completely reworked.
    • SAT SSI: Implementation is now based on modernized Dissector-API.
    • Raw data serial: Implementation is now based on modernized Dissector-API.
    • Raw data Network: Implementation is now based on modernized Dissector-API.
    • Many minor improvements ...

  • General:
    • COMPROTware:Testtool is now also running on Microsoft Windows Vista, Windows 7, Windows Server 2008 and Windows Server 2008 R2.
    • Support of Java 7.
    • The Message View can now be scrolled up and down by the mouse wheel.
    • Protocol traffic monitoring at one serial or network interface of ABB MicroSCADA Pro with RIO Server (no extra CPRIOServer license required).
    • Modernization of program core.
    • Correction to User Engine Classes and Normalized Messages for IEC 60870-5-101 and -104.
    • Many minor improvements ...

  • GUI:
    • New check box "Show erroneous Messages" in window "Formatting Options" to show or filter all erroneous frames and message (received while simulating or monitoring over modem connection).
    • Some errors occuring when searching for strings in the Message View are fixed.
    • Many minor improvements ...

  • Transmission Protocols:
    • IEC 60870-5-101 & IEC 60870-5-104: Graphical User Interface of Filetransfer-User Engine Class now implemented as a wizard.
    • IEC 60870-5-104: During network monitoring VLAN is recognized and correctly handled.
    • DNP3 serial & DNP3 over LAN/WAN: Single- and double-precision floating-point values are now supported for Object groups 30, 31, 32, 33, 40 und 41.
    • DNP3 serial & DNP3 over LAN/WAN: The protocol presentations was extended by the Object Groups Double-bit Binary Input (Object Group 3) and Double-bit Binary Input event (Object Group 4). The Edit Message window now supports the Object Groups/Variations 3/1, 3/2 and 4/1.
    • Many minor improvements ...